Skip to main content
Components | Solutions | Systems for:

Low pressure regulator G76

for connection of caravans and motor caravans with gas equipment running on 30 mbar to stationary gas lines 50 mbar


  • the low pressure regulator is installed in the stationary gas line outside the vehicle and regulates the pressure from 50 to 30 mbar

  • The low pressure regulator is not suitable for installation in the vehicle!
  • In the German DVGW worksheet G 607 for LPG systems in occupied leisure vehicles and for living purposes in other road vehicles, it is prescribed in the chapter for operation and testing that pressure regulators are to be replaced 10 years after the date of manufacture at the latest. If the working pressure of the system is 30 mbar, pursuant to G 607, a regulator according to EN 16129, annex D (e.g. part no. 01 280 10) is to be used in the event of a replacement. For LPG systems in vehicles with a working pressure of 50 mbar, a non-compliance permit applies. There is no obligation to convert to 30 mbar.
Filter

Connection A
Connection B
Outlet pressure
Flow rate
Inlet/Outlet
Packaging
Part no.
compr. fit. 8
compr. fit. 8
30 mbar
1.5 kg/h
straight
0145000
compr. fit. 8
compr. fit. 8
30 mbar
1.5 kg/h
straight
6145001