Level gauge type FSA for GWD/FSS


















Level gauge type FSA for GWD/FSS
Application example:
On each tank of a battery tank system, the filling height can be read in a standardised way, simply and reliably with the level gauge type FSA.
The limit indicator in the first tank is arranged in a unit:
- as limit indicator type GWD with level gauge type FSA
or
- as limit indicator type FSA for GWD/FSS with an additional integrated limit indicator.
Note:
Instructions, a table or device to convert the filling height into volume must be affixed to the tank or provided.
for mechanically determining the filling level with display of the filling height in non-pressurized tanks and bore for the secure and odour-free attachment of a limit indicator, filling level limiter or probes of overfill prevention devices, e.g. type BC-1 with a probe tube diameter of 10 mm
consisting of: level gauge type FSA, with pre-mounted lock ring, O-ring, fixing screws and loose rope haulage
- high measuring accuracy
- determination of the filling height according to the float principle
- subsequent marking for the maximum filling height corresponding to the maximum admissible filling volume
- odour-free version
- with insufficiently translucent walls of above-ground tanks, simple retrofitting via a free screw-in opening
- at the free connection of the tank, the level gauge can be optionally retrofitted with a limit indicator or a filling level limiter
- measuring accuracy: ± 3 %
- tight at test pressure: up to 100 mbar
- float diameter: 31 mm
- material: housing: ABS
float: PE-HD
spring: stainless steel, material no. 1.4310
- The level gauge FSA for GWD/FSS is only odour-free with a mounted probe tube.
- The limit indicator type GWD or the level gauge FSS are not included in the scope of delivery!