for non-pressurised tanks with a liquid operating medium


Operating media:
kerosene and petrol

Function:
Level probes are equipped with a pressure sensor and measure the hydrostatic pressure of a liquid column. The electronics in the level probe convert the signal into a 4-20 mA output signal.

  • extension of the probe cable up to a maximum of 200 m
  • high-strength FEP cable with Teflon double sheath

  • measurement range 250 mbar: petrol up to 3.30 m tank height
  • tank connector: G 1 M

  • When selecting level probes, the suitability, the density value of the operating medium and the tank height are to be taken into account.

Other configurations, media and probe measuring ranges on request.

When selecting the level probe, the tank height and density value of the operating medium must be taken into account. This is the only way to select the correct measuring range. Please also ensure that the level probe is suitable for the medium in use.
Filter

Article name
Packaging
Part no.
EX protection zone level probe 0 to 250 mbar with 5 m cable(for use only in conjunction with explosion-proof barrier 28 861 00)
2884600

Article name
Packaging
Part no.
Explosion-proof barrier (required for level probes used in hazardous areas)
2886100
IP65 housing, for explosion-proof barrier
2886500
cable connection box IP66 breathabel for EX protection zone
2886700